Date Description Inspector Results Comments
07/21/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000* WILL HAVE LISTING ON HEADESS BY INTERM
07/18/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) PATIO BEAM NOT STRAPPED AND FRAMING MISSING ABOVE COLUMN 2) MUD SILL STRAPS NOT NAILED AT COLUMN 3) SEE NOTES FROM 7/15/03
07/16/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) CANCELLED BY SUPER
07/15/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) HEADERS NOT TO SIZE SHOWN ON LINTLE SCHEDULE MARKED ON FLOOR 2) CROSS BRACES NAILED TO TRUSS AT ENDS, NAILS TO BE IN SHEAR 3) BLOCK AND NAIL ALL MUD SIZE HOLES, AT REAR SOFFIT CUT INTO WALL BLOCK AND WALL PERIMETER 3) FLAT BLOCK UNDER HOLE IN ROOF DECK GARAGE