Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM02940

Parcel: 105102440


Addresses:

495 E WETMORE RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/27/2004 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) ALL INDIRECT WASTE PIPING TO CONFORM TO 94 UPC 2) REINSPECTED 2:00 PM. BACKFLOW CERTS ON FILE WITH TUCSON WATER 3) ALL REVISED PLANS ON SITE 4) OK FOR C OF O PENDING ANY OTHER INSPECTIONS
01/26/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) GAS TO ROOFTOP UNIT OK SUBJECT TO REVISED APPROVED PLAN. OK TO MAKE FINAL CONNECTIONS. 2) INDIRECT WASTE PIPING GREATER THAN FIVE FEET REQUIRED TO BE DIRECTLY TRAPPED. 3) RECUCING PIPING NOT APPROVED.
01/23/2004 PLUMBING - FINAL Not ready for Inspection
01/22/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) PLEASE PROVIDE APPROVED REVISED PLAN FOR UNDERGROUND. 2) PROVIDE TESTING ON ALL BACKFLOW DEVICES.