Permit: T03CM02940

Parcel: 105102440


Addresses:

495 E WETMORE RD

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
01/16/2004 PLUMBING - INTERMEDIATE Approved 1) ABS DWV THRU ROOF OK. 2) COPPER OK. 3) OK TO COVER WALL.
01/15/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/ 1) PROVIDE INSPECTION HISTORY WITH APPROVAL TO COVER WALLS. 2) ALL PIPING TO BE INSTALLED TO 94 UPC TABLE 3-1 AND APPROPRIATE INSTALLATION STANDARD. 3) PLUMBERS TAPE NOT APPROVED STRAPPING. 4) A CLEAN OUT TEE MAY NOT BE INSTALLED ON ITS BACK IN HORIZONTAL POSITION. INSPECTION STOPPED.