Permit: T03CM02899

Parcel: 128100800

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T03CM02899

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/25/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
09/24/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/1) NORTH WALK-IN UNIT REQUIRES A DISCONNECTING MEANS WITHIN SIGHT. 2) ILLUMINATION REQUIRED ABOVE WALK-INS IN CONCEALED AREA. 3) MAINTENANCE RECEPTACLE REQUIRED AT EACH.
09/22/2003 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*/ OK TEMP POWER AND FUEL TEST.
09/18/2003 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*/ CORRECTIONS: 1) CHECK THE SIEMENS TRANSFORMER INSTALLATION INSTRUCTIONS TO SEE IF AN EMBERS PLATE IS REQUIRED BENEATH THE TRANSFORMER. 2) THE WATER HEATER DISCONNECT DOES NOT HAVE THE REQUIRED CLEARANCES. 3) ALL DISCONNECTS NEED TO BE MARKED WITH THE PANEL NAME AND CIRCUIT NUMBERS. FOR INTERIOR MTL A "MAGIC MARKER" WILL DO. FOR EXTERIOR MTD USE METALLIC EMBOSSED STRIP. 4) BE SURE ALL EBO AND EXIT LIGHTS ARE CHARGED AND OPERABLE. AN ACTIVE DEMONSTRATION IS REQUIRED. 5) ALL EQUIPMENT SHOULD BE SET IN PLACE, PLUGGED IN, AND OPERABLE. RECALL.
09/15/2003 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*