Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM02897

Parcel: 140374390


Addresses:

6186 E STONECHAT DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/08/2003 FRAMING Approved IVRS - Inspection 0000*
10/07/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) NAIL PROTECT ELECTRIC WITHIN 1 1/4" FROM EDGE OF STUD 2) NO TEST ON DWV'S UPSTAIRS 3) NAIL PROTECT WATER LINE MASTER BATH 4) FIRE BLOCK STRINGER AT GARAGE AND PLATFORM 5) CLIP STAIR STRINGERS 6) NAIL PROTECT COPPER LINE BOTH SIDES 7) WATER LINES OK
10/06/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) CANCELLED ON SITE BY SUPER
10/03/2003 FRAMING Denied IVRS - Inspection 0999*