Permit: T03CM02896

Parcel: 137276240


Addresses:

6186 S TRUMAN DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/01/2003 FRAMING Approved IVRS - Inspection 0000*
08/29/2003 FRAMING Partial Approval IVRS - Inspection 0000*/1) GROUND METAL CEILING BOX. ALL ELSE OK. 2) PROVIDE 100 SQ. INCH HIGH AND LOW COMBUSTION AIR FOR WATER HEATER.
08/06/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) A/C UNIT REQUIRES A DEDICATED 20 AMP ELECTRIC CIRCUIT 2) GAS METER VENT MUST BE 36" FROM WINDOW OPENING AND A/C INTAKE 3) RELOCATE A/C UNIT 4) INSTALL JACK STUDS UNDER HEADER FOR A/C UNIT