Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM02882

Parcel: 103183440

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T03CM02882

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
09/04/2003 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000* 1) EXHAUST FAN IN MASTER BATH MISSING FLAPPER & LAUNDRY. 2) BLOCK MECHANICAL AT 2ND FLOOR LANDING. 3) NO RETURN AIR. 4) DISCONNECT NOT HOOKED UP TO UNIT. 5) NAIL PROTECT CONDESATE LINES AND SECURED. 6) SEALL ALL MOISTURE BARRIER PENETRATIONS. 7) PROVIDE BACKING AT SHOWER MASTER BATH.