Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T03CM02837
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/31/2003 | ROOF NAILING | Approved | IVRS - Inspection 0000* | |
07/30/2003 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection 0000* 1) H 1 D TRUSS IN GARAGE GETS T BRACED- SEE TRUSS DRAWINGS. 2)MOVE TRUSS R 1 A OVER FULL BEARING AT ENTRY DIAGONAL WALL. 3) SHEAR WALL AT GARAGE TO HOUSE, NAIL WITH 8d 6"o.c. DBL. TOP PLATE TO ROOF DECK SHEAR TRANSFER. 4) SUPPORT WALL FOR TOWER ENTRANCE, MARKED IN BLACK. 5) 10) SOLID BLK UNDER PLATE FOR ENTRY TOWER, SEE ROOF FRAME PLAN. 6) WALKED ROOF ALL OTHER NAILING OK |