Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/23/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 07/22/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) RIDGE BLOCKS MISSING 2) TRUSS R1 X A AT FRONT ENTRY REQUIRES ENGINEER REPAIR 3) CHECK FOR OVER SPAN FRAMING |
| 07/21/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) INSTALL TRIPLE POST AT GIRDER 2) SHIM AND A34, H2.5 HEADERS 3) SUPPORT FOR LATERAL ROTATION AT STUB TRUSSES 4) INSTALL RIDGE BLOCKING 5) 4" EDGE NAILING AT SHEAR 5 6) INSTALL GABLE BRACING PER DETAIL 10 |
| 07/18/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |