Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM02829
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/09/2004 | FRAMING | Approved | IVRS - Inspection 0000* | |
02/02/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) FIRE BLOCK MISSING AT FUR DOWNS 2) 1" CLEARANCE REQUIRED AT B-VENT FROM COMBUSTIBLES 3) H2.5'S MISSING AT BEARING WALL 4) CHECK FOR BANG PLATES THRU-OUT 5) GROUND ALL METAL BOXES 6) ELECTRIC UPGRADE CONNECTED BY TEP WITHOUT CLEARANCE OR APPROVAL BY DSC 7) EXPOSE GROUND RODS | |
01/09/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |