Date Description Inspector Results Comments
10/24/2003 BUILDING - FINAL Approved IVRS - Inspection 0000*
10/23/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) PRV TO OUTSIDE MISSING 90 DEGREE ELBOW 2) SECURE WHIP AT CONDENSOR 3) PROVIDE POSITIVE FLOW AT WATER HEATER PRV 4) CLEAN SECONDARY PAN 5) FAU NOT HOOKED UP TO GAS LINE, IE... NO FLEX, NO SHUT OFF VALVE 6) B-VENT MISSING CAP