Permit: T03CM02817

Parcel: 10408051B


Addresses:

4565 N ORACLE RD


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T03CM02817

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/02/2003 PLUMBING - FINAL Approved
12/01/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) SOAP DISPENSERS REQUIRE BACKFLOW PROTECTION. NOTE: DO NOT USE VACCUM BREAKER 2) INDIRECT WASTE PIPING LESS THAN 5 FEET DOES NOT NEED USE APP. MAT'L TRAP OR VENT. BETWEEN 5' AND 15' MUST BE DIRECTLY TRAPPED SUPPORT ALL INDIRECT WASTE PIPING 3) CAULK ALL FIXTURES 4) DRAIN ON 007 NOT RUN