Permit: T03CM02814

Parcel: 138241980

Inspection Status: Approved

Inspection History: STUCCO MESH

Date Description Inspector Results Comments
07/29/2003 STUCCO MESH Approved IVRS - Inspection 0000*
07/28/2003 STUCCO MESH Denied IVRS - Inspection 0999* 1) STUCCO CORNER REINFORCEMENT NOT INSTALLED N. W. CORNER 2) SHEAR WALLS #5 REQUIRE 5 D NAILS AT 4" O.C 3) #1 SHEAR WALLS REQUIRE 5 D NAILS AT 7'' O.C. SCREWS NOT ALLOWED