Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM02812

Parcel: 116035790


Addresses:

1506 N OLD RANCH RD


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM02812

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/24/2003 FRAMING Approved IVRS - Inspection 0000*
07/23/2003 FRAMING Denied IVRS - Inspection 0160*/ 1) NAIL GARAGE POSTS PER DETAIL 2) INSTALL A.35'S PER DETAIL AT GARAGE SHEAR 3) AB'S AT 24" ON CENTER AT GARAGE WALL 4) SECURE AB'S THROUGHOUT 5) SECURE J-BOX AT BR #3 6) NAIL PLATE AT ENTRY 7) COMPLETE LATH 8) SHIM HEADERS 9) STRAP TOP PLATE AT WATER HEATER STAND 10) SUPPORT BEAM AT GARAGE WALL AT STAND