| 07/23/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
| 07/22/2003 | FRAMING | Denied | IVRS - Inspection 0160*/ 1) REVIEW ALL DETAILS 2) SEE PREVIOUS INSPECTION | |
| 07/21/2003 | FRAMING | Denied | IVRS - Inspection 0160*/ 1) TAPE ALL PAPER TEARS 2) FIRESTOP AT PANTRY 3) SECURE AB'S 4) STRAP TOP PLATES AT PLUMBING IN GARAGE AND MASTER BATH 5) SEAL A/C LINE IN GARAGE 6) SUPPORT DUCTS PER CODE 7) BLOCK OUT VENT IN D.R. | |
| 07/18/2003 | FRAMING | Denied | IVRS - Inspection 0950*/ 1) ATTACH A3.5'S AT GARAGE WALL TO TRUSS CHORD 2) INSTALL GABLE BRACING PER DETAIL 3) INSTALL BLOCKING AT #3 SHEAR 4) NAIL GARAGE POSTS 5) COMPLETE NAILING AT BLOCKING PANELS 6) NAIL PLATE WASTE 7) NO DUCTS AT SUPPORT FOR WATER LINES 8) NO TEST ON WASTE 9) 50 PSI AIR TEST ON WATER LINES 10) SEAL A/C LINE IN GARAGE 11) SUPPORT DUCTS PER CODE 12) NOTE: THIS WAS NOT A COMPLETE INSPECTION | |
| 07/17/2003 | FRAMING | Denied | IVRS - Inspection 0160*/ 1) SECURE AB'S 2) REPAIR TEARS IN PAPER 3) SECURE WATER LINES IN WALL 4) TEST WASTE 5) BLOCK VENTS |