Permit: T03CM02807

Parcel: 11702367A


Addresses:

925 N 11TH AV

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/22/2004 BUILDING - FINAL Approved IVRS - Inspection :*
10/14/2004 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) ADDITIONAL ELECTRIC OUTLET IS REQUIRED AT KITCHEN EAST WALL 2) ALL KITCHEN COUNTER TOP OUTLETS MUST BE GFCI PROTECTED 3) OUTLET OF ISLAND HAS NO POWER 4) WATER HEATER TEMP/PRESUURE RELIEF VALVE MUST DISCHARGE TO EXTERIOR 5) PRVOIDE GDCI OUTLET AT MASTER LAVATORY 6) PROVIDE ACCESS PANEL TO WHIRLPOOL PUMP/MOTOR 7) EXTERIOR LIGHT IS REQUIRED AT ALL EXIT DOORS 8) STOOP OR LANDING IS REQUIRED AT EXIT DOORS 3' X 3'