Permit: T03CM02798

Parcel: 131114160


Addresses:

5648 E 35TH ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/18/2003 FRAMING Approved
09/19/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) STRAP SOUTH EAST CORNER TOP PLATES AROUND OUTSIDE 2) LAG BOLT NEW WEST RAFTER TO OLD ONE 3) BEARING STUD NEXT TO PLUMBING VENT MUST BE BEARING 4) FHA STRAP CUT BOTTOM PLATE TOGETHER 5) BANG PLATE (METAL PROTECTION PLATES) ALL PLUMBING AND ELECTRIC THAT IS WITHIN 1 1/4" OF THTE FACE OF STUDS AND PLATES 6) SECURE (STAPLE) ALL WIRING WITHIN 12" OF EACH FIXTURE 7) SUPPORT BRICK LENTIL AT WEST END OF NEW GIRDER 8) DRAINAGE, WASTE, VENT (DWV) TEST NEEDED FOR PLUMBING INTERMEDIATE 9) NOTE: ALL INTERMEDIATE INSPECTIONS MUST PASS BEFORE FRAME PASSES
09/18/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*
09/16/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*