Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/18/2003 |
FRAMING |
|
Approved |
|
| 09/19/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) STRAP SOUTH EAST CORNER TOP PLATES AROUND OUTSIDE 2) LAG BOLT NEW WEST RAFTER TO OLD ONE 3) BEARING STUD NEXT TO PLUMBING VENT MUST BE BEARING 4) FHA STRAP CUT BOTTOM PLATE TOGETHER 5) BANG PLATE (METAL PROTECTION PLATES) ALL PLUMBING AND ELECTRIC THAT IS WITHIN 1 1/4" OF THTE FACE OF STUDS AND PLATES 6) SECURE (STAPLE) ALL WIRING WITHIN 12" OF EACH FIXTURE 7) SUPPORT BRICK LENTIL AT WEST END OF NEW GIRDER 8) DRAINAGE, WASTE, VENT (DWV) TEST NEEDED FOR PLUMBING INTERMEDIATE 9) NOTE: ALL INTERMEDIATE INSPECTIONS MUST PASS BEFORE FRAME PASSES |
| 09/18/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 09/16/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |