Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/07/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/03/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) SMOKE DETECTOR IN MASTER BEDROOM NOT SECURED AND NEEDS TO BE 3' FROM REGISTER |
| 10/01/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NO WEEP SCREED AT COLUMNS (LATH) 2) CUPS MISSING AT SHEER WALL GARAGE TO BOTTOM COND. 3) SMOKE DETECTOR IN BEDROOM NEEDS TO BE 3' AWAY FROM REGISTER 4) OK TO INSULATE |
| 09/29/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) STAPLES MISSING AT GARAGE POP OUTS 2) SEAL AROUND EAVES AND ALL PENETRATIONS 3) STAPLES MISSING GARAGE AREA, VERTICAL JOINTS TAPE MISSING OR NOT CAULKED TO STANDARDS 4) EAST SIDE OF HOUSE NOT LATH 5) RECALL WHEN LATH IS COMPLETE |