Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/03/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) CORRECTIONS MADE OK 2) CERTIFICATIONS ON FILE WITH TUCSON WATER 3) OK FOR C OF O PENDING ANY OTHER INSPECTION |
| 10/23/2003 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) PLEASE PROVIDE CORRECT AIR GAP AND TERMINATION OF PIPING AT FLOOR SINK IN COFFEE BAR AREA. 2) PLEASE HAVE RPB CERTIFICATION COMPLETED. |
| 10/21/2003 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) WATER HEATER REQUIRES PAN AND DRAIN. 2) INDIRECT WASTE PIPING BETWEEN 5-15' REQUIRES A TRAP. 3) EACH WATER OPERATED PEICE OF EQUIPMENT REQUIRES ITS OWN REDUCED PRESSURE AND OR BACKFLOW DEVICE. 4) PROVIDE CERTIFICATION ON BACKFLOW PREVENTORS. |
| 10/06/2003 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/THIS INSPECTION IS FOR TEMP. POWER FOR TESTING (NO CODE) APPROVED. |