08/18/2003 FRAMING Approved IVRS - Inspection 0000*
08/15/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) BEARING AT GARAGE HEADER 2) LETTER FROM ENGINEER ON TRUSS PLATES 3) AB'S AT SW4 4) STRUD REPAIR IN GARAGE 5) COMPLETE LATH AND VAPOR BARRIER 6) NAIL PLATE THROUGHOUT
08/14/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) STRAP GARAGE WALL 2) RETRO HOLDOWN AT REAR 3) NAIL PLATE ELECTRIC IN GARAGE, THROUGH OUT 4) NAIL KINGS PER DETAIL 5) TEST WASTE 6) A35 AT 12" ON CENTER AT GARAGE SHEAR 7) SUPPORT GARAGE WALL AT HEADER 8) TRUSS BRACING AT H1, R1B, R1D, R1ES 9) TRUSS FIXES AT PLATE ON 10) 50 PSI AT WATER LINE 11) SEAL VAPOR BARRIER