Permit: T03CM02749

Parcel: 116035260


Addresses:

2322 W PAINE TR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/06/2003 FRAMING Approved IVRS - Inspection 0000*
08/04/2003 FRAMING Denied IVRS - Inspection 0160*/ 1) SECURE AB'S 2) A34 ALL HEADERS 3) SHIM GIRDER POST IN FRONT BEDROOM 4) FIRE STOP AT GARAGE DROP AND HALL BATHS 5) NAIL H2.5'S PER MGF. 6) DOUBLE TRIMMERS AT HEADERS UNDER 6'-3 OVER 6' 7) NAIL PLATE WATER 8) NO TEST ON WASTE 9) SUPPORT WASTE LINES PER CODE 10) PROTECT WASTE IN FRONT BEDROOM CLOSET 11) SUPPORT DUCTS PER CODE-REPAIR ALL TEARS 12) SEAL VAPOR BARRIER
07/29/2003 FRAMING Denied IVRS - Inspection 0160*/ 1) SEE PREVIOUS INSPECTION WHICH WAS NOT A COMPLETE INSPECTION
07/28/2003 FRAMING Denied IVRS - Inspection 0160*/ 1) SECURE AB'S 2) NAIL SHEAR 5 PER DETAIL 3) REMOVE INSULATING MATERIAL FROM WALLS 4) NOT COMPLETED 5) REPAIR/REPLACE 220V IN GARAGE 6) NAIL PLATES 7) TEST ALL WASTE LINE 8) SUPPORT PER CODE 9) NOTE: NOT A COMPLETE INSPECTION