Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/05/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 08/04/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0160*/ 1) NAIL SHEAR PER DETAIL 2) SECURE AB'S 3) OVER SPANNED STUDS IN GARAGE 4) INSTALL POSTS AT GARAGE PER DETAIL, (KINGS-TRIMMERS) 5) INSTALL OVERFRAME PER DETAIL 6) RISER AND GROUND NOT INSTALLED 7) NAIL PLATE ELECTRICAL 8) SD IN HALL TO CLOSE TO RETURN 9) ADD SD AT 24" DROP FROM MASTER BEDROOM 10) NAIL PLATE WATER LINES 11) SUPPORT DUCTS PER CODE 12) SEAL VAPPOR BARRIER 13) CAULK J-BOXES 14) STRAP OVER BOARD STUDS IN EXTERIOR WALLS 15) NAIL ALL H2.5'S 16) INSTALL TRIPLE POST AT GARAGE WALL PER PLAN 17) FIRE STOP SHAFT AT MASTER BEDROOM 18) SUPPORT HEADER NEAR ENTRY NOTE: PROVIDE THE ENGINEERS APPROVAL FOR TECO OSB |
| 07/29/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0160*/ 1) SEE PREVIOUS INSPECTION |
| 07/28/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) ROOF NOT LOADED 2) WASTE LINES NOT TESTED 3) NAIL PLATES AT PLUMBING AND ELECTRIC 4) SECURE AB'S AND HOLDOWNS 5) INSTALL RETRO HOLDOWNS AT REAR 6) COMPLETE J-BOX AT REAR BATH 7) SEAL VAPOR BARRIER |