Inspection History Details
Permit: T03CM02744
Inspection Status: Approved
Inspection History: PLUMBING - ABOVE CEILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/24/2005 | PLUMBING - ABOVE CEILING | Approved | IVRS - Inspection :* | |
| 10/05/2004 | PLUMBING - ABOVE CEILING | Denied | IVRS - Inspection : 1) ALL THREADED ABS FITTINGS THAT HAVE VECTOR SEAL # 5 ON THEM SHALL BE UNSCREWED THOROUGHLY CLEANED, AND REASSEMBLEAD ( READ THE CAN). 2) SHEET ROCK SCREWS ON CLOSET FLANGES NOT ALLOWED. 3) A TRAP ARM MAY ONLY CHANGE DIRECTION 90 DEGREES WITHOUT AN ADDITIONAL CLEAN -OUT RESTRICTED TO 1/4" PER FOOT . 4) ONE MORE TIMES CHANGE OF DIRECTION, CHANGE OF ELEVATION AND AT THE END OF BRANCHES-THEN EVERY SO MANY FEET TABLE 3-1 |
|
| 09/30/2004 | PLUMBING - ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* |