Permit: T03CM02744


Addresses:

136 E LIMBERLOST DR

Inspection Status: Approved

Inspection History: PLUMBING - ABOVE CEILING

Date Description Inspector Results Comments
01/24/2005 PLUMBING - ABOVE CEILING Approved IVRS - Inspection :*
10/05/2004 PLUMBING - ABOVE CEILING Denied IVRS - Inspection :
1) ALL THREADED ABS FITTINGS THAT HAVE VECTOR SEAL # 5 ON THEM SHALL BE UNSCREWED THOROUGHLY CLEANED, AND REASSEMBLEAD ( READ THE CAN). 2) SHEET ROCK SCREWS ON CLOSET FLANGES NOT ALLOWED. 3) A TRAP ARM MAY ONLY CHANGE DIRECTION 90 DEGREES WITHOUT AN ADDITIONAL CLEAN -OUT RESTRICTED TO 1/4" PER FOOT . 4) ONE MORE TIMES CHANGE OF DIRECTION, CHANGE OF ELEVATION AND AT THE END OF BRANCHES-THEN EVERY SO MANY FEET TABLE 3-1
09/30/2004 PLUMBING - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*