02/04/2004 ROOF NAILING Approved IVRS - Inspection 0000*
11/19/2003 ROOF NAILING Partial Approval IVRS - Inspection 0000*/ 1) FRONT MAIN HOUSE EXCEPT FOR REAR PORCH OK REAR GUEST HOUSE OK
11/17/2003 ROOF NAILING Denied IVRS - Inspection 0999*/ 1) NEED APPROVED TRUSS DRAWINGS FROM MANUFACTURER 2) POSITIVE CONNECTION JACK TRUSSES AT BEARING 3) TRUSSES NOT INSTALLED PER PLAN 4) PORCH INCOMPLETE