Permit Number - T03CM02722
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/05/2003 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000* | |
06/05/2003 | PLUMBING - ROUGH, SOIL | Partial Approval | 1) REQUIRED WATER TEST IS A MINIMUM TEN FOOT HEAD 2) PIPING SHALL BE LAID ON A FIRM BED. BRIDGING IS NOT ALLOWED 3) ALL PIPING EXPOSED TO CONCRETE SHALL BE WRAPPED. CALL FOR 03005 ROUGH/SOIL INSPECTION PRIOR TO POURING CONCRETE 4) OK TO COVER |