Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T03CM02720
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/15/2004 | ROOF NAILING | Approved | IVRS - Inspection :* | |
12/06/2004 | ROOF NAILING | Partial Approval | IVRS - Inspection :*/ 1) OVER FRAME AREA NOT NAILED | |
11/19/2004 | ROOF NAILING | Partial Approval | IVRS - Inspection :*/ 1) ROOF OVER GARAGE OK 2) HOUSE OVER FRAME OK. BUT SHEATHING OVER THAT AREA NOT NAILED |
|
10/29/2004 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) ROOF PANELS MUST BE NAILED MAXIMUM SPACING OF 6" ON CENTER AT ALL SUPPORTED ENDS AND EDGES AND 12" ON CENTER IN FIELD TO TRUSSES BELOW 2) PLYWOOD PANELS MUST BE INSTALLED WITH GRAIN PERPENIDCULAR TO SUPPORTING TRUSSES 3) ROOF PANELS MUST SPAN THREE TRUSSES ( 2 BAYS). REPLACE ALL SMALL PANELS 4) TRUSS CLIPS MUST BE ANILED WITH ALL HOLES FILLED USE H2.5 CLIPS 5) ANCHOR BOLTS REQUIRED WITHIN 12" OF ALL PLATE ENDS AND SPLICES AND EVERY 6 FEET THERE AFTER 6) EXPOSE OVER BUILT FRAME 7) PROVIDE COMPLETE CITY APPROVED PLANS 8) OVER FRAME REQUIRES 2 X 8 VALLEY BOARD |