Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM02702
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
| 07/15/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) INSTALL KINGS AT GARAGE HEADER 2) NAIL SHEAR AT GARAGE WALL PER DETAIL 3) INSTALL GABLE BRACING PER DETAIL 4) INSTALL A35'S AT GARAGE GABLE AND REAR 5) SECURE WIRE AT SWITCH ON PANTRY 6) SUPPORT ALL DUCTS 7) ATTACH FLUE OFFSET SUPPORT AT FIREPLACE 8) SECURE RED HEADS AND H.D.'S 9) FIRESTOP DROP AT HALL BATH NEAR TUB AND PANTRY 10) CLIP AND SHIM 3 PT BEARING 11) ADD FIRESTOPS IN HALL | |
| 07/14/2003 | FRAMING | Denied | IVRS - Inspection 0950*/ 1) 2ND STOP | |
| 07/11/2003 | FRAMING | Denied | IVRS - Inspection 0950* |