Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/28/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 08/26/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) RAT RUN A-11 TRUSSES 2) MARKED MISSING NAILING ON ROOF 3) NAIL ALL SHEAR PANELS TO ROOF WITH 8D'S 6" ON CENTER 4) 2 NAILS IN EACH END OF EACH WIND BRACE |
| 08/25/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) CLIP STUD TO PLATES FRONT ENTRY DROP 2) NAIL CORNER FRONT/WEST, TIE POPOUT TO WALL (BIG WINDOW) 3) MORE 16D'S AT REAR LEDGER TO WALL 4) TWO NAILS INTO EACH PLATE METAL WIND BRACE 5) ADD NAILS AT ROUGH SAW LOOK OUT EAST WALL 6) EAST SIDE GARAGE WALL SUPPORTING BEAM ANCHOR PLATE WITH BOLTS 7) FINISH NAILING CLIPS AT FRONT GARAGE BEAM 8) NAIL SHEAR ABOVE WINDOW FRONT AT BOTTOM EDGE 9) PLEASE ASK TRUSS MANUFACTURER ABOUT GAP AT TOP CHORD BEARING TRUSS |