Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM02695
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/25/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
11/24/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) NO TEST ON DWV'S 2) AS PER TABLE E-3702.1 IRC FLAT CABLES SHALL NOT BE STAPLED ON EDGE (ROMEX) 3) OVERSPAN AT WATER HEATER 4) SEAL ALL MOISTURE BARRIER PENETRATIONS 5) NAIL PENETRATED ROMEX AT LEFT SIDE ENTRY 6) INSULATE BEHIND TUB 7) NAIL PROTECT ALL PLUMBING WITHIN 1 1/2" FROM EDGE OF STUD ON HORIZONTAL AND VERTICAL RUNS 8) GAS PRESSURE AT 2 PSI +, 10 PSI REQUIRED 9) STOPPED INSPECTION TO MANY ITEM RECALL WHEN READY | |
11/20/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) COMPLETE LATH, NEXT INSPECTION IF NOT CORRECTED WILL REFEE | |
11/17/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) COMPLETE LATH BEFORE CALLING FOR INTERMEDIATES |