Permit: T03CM02688

Parcel: 103183580

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM02688

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/19/2003 FRAMING Approved IVRS - Inspection 0000*
08/15/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) SUPPORT VENT DWV AT KITCHEN 2) STAIR TOP OF STRINGERS REQUIRE LEDGERS 3) #1 SHEAR WALL NOT SHEARED AT DINNING ROOM 4) INSULATE RETURN AIR DUCT SLEEVE 5) A/C DISCONNECT ATTIC OBSTRUCTION 6) OK TO INSULATE ALL BUT ?
08/14/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*
08/13/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) HOUSE HAS BEEN INSULATED WITHOUT INTERMEDIATES INSPECTIONS. REMOVE INSULATION
08/11/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) NOT COMPLETED
08/08/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*