Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/19/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 08/15/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) STUCCO LATH MUCH FOAM DOES NOT HAVE ? AND ?. PROVIDE COMPLETE ICBO INSTALLATION STANDARD AND INSTALL PER STANDARD 2) HALL BATH WATER CLOSET IMPROPERLY FLAT VENTED 3) #1 SHEAR WALL MUS BE CONNECTED TO EXTERIOR WALL. REMOVE FURR OUT WALL AND SHEAR #1 WALL AT LIVING ROOM 4) STAIRS REQUIRE LEDGERS AT TOP END PER 15/D-1 5) POST MUST BEAR BEAM ABOVE STAIR 6) INSULATE RETURN AIR DUCT SLEEVE 7) A/C DISCONNECT IN ATTIC MUST HAVE 30 X 30 WORK AREA |
| 08/14/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |