Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM02687
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/19/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
| 08/15/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) STUCCO LATH MUCH FOAM DOES NOT HAVE ? AND ?. PROVIDE COMPLETE ICBO INSTALLATION STANDARD AND INSTALL PER STANDARD 2) HALL BATH WATER CLOSET IMPROPERLY FLAT VENTED 3) #1 SHEAR WALL MUS BE CONNECTED TO EXTERIOR WALL. REMOVE FURR OUT WALL AND SHEAR #1 WALL AT LIVING ROOM 4) STAIRS REQUIRE LEDGERS AT TOP END PER 15/D-1 5) POST MUST BEAR BEAM ABOVE STAIR 6) INSULATE RETURN AIR DUCT SLEEVE 7) A/C DISCONNECT IN ATTIC MUST HAVE 30 X 30 WORK AREA | |
| 08/14/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |