Inspection History: FRAMING

Permit Number - T03CM02687

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/19/2003 FRAMING Approved IVRS - Inspection 0000*
08/15/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) STUCCO LATH MUCH FOAM DOES NOT HAVE ? AND ?. PROVIDE COMPLETE ICBO INSTALLATION STANDARD AND INSTALL PER STANDARD 2) HALL BATH WATER CLOSET IMPROPERLY FLAT VENTED 3) #1 SHEAR WALL MUS BE CONNECTED TO EXTERIOR WALL. REMOVE FURR OUT WALL AND SHEAR #1 WALL AT LIVING ROOM 4) STAIRS REQUIRE LEDGERS AT TOP END PER 15/D-1 5) POST MUST BEAR BEAM ABOVE STAIR 6) INSULATE RETURN AIR DUCT SLEEVE 7) A/C DISCONNECT IN ATTIC MUST HAVE 30 X 30 WORK AREA