Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/15/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/14/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) BANG PLATE DRYER VENT AT TOP AND WIRES 3' TO WEST OF DRYER VENT 2) REMOVE STAPLES AND NAILS BEHIND ELECTRIC AND WATER HOME RUNS 3) REPAIR FIREBLOCKING WHERE NEEDED 4) SHIM HEADERS WHERE NEEDED 5) BLOCK MECH PLATFORM PERIMETER 6) SECURE 4 GANG AT ENTERTAINMENT CENTER AND 2 AT ENTRY AND KITHCEN HALL-2 7) MORE PEX FROM CAN IN W. HALLWAY 8) PROVIDE 1" TO OSB AT EAST FURNACE FLUE 9) REPLACE I-JOIST BRACKET IN S.E. BEDROOM 10) CAULK OUTLET BOXES, WOOD THROUGH FOAM AND WATER MAIN 11) BBQ AREAS NOT MESHED |
|
| 06/07/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |