Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/16/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000*/ 1) NOTE: NO KITCHEN ISLAND |
| 10/14/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0935*/ 1) NAIL PROTECT ALL PLUMBING WITHIN 1 1/4" OF STUD WALL SURFACE 2) GAS LINE GREATER THAN 36" FROM FURNACE 3) MECHANICAL DUCT RESTRICTED AT MASTER BATH BEND GREATER TAHN 1 DUCT DIAMETER RADIUS 4) NAIL PROTECT ALL WIRES WITHIN 1 1/4" OF STUD WALL SURFACE 5) SECURE WIRES WITHIN 8" OF ELECTRIC BOXES 6) NON BEARING STUDS NOTCHED GREATER THAN 40 PERCENT (REPLACE) 7) THIRD FAILURE YOU MUST PA A REFEE PRIOR TO NEXT INSPECTION |
| 10/13/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) "B" VENT MUST BE 1" FROM COMBUSTIBLE ? 2) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD/WALL SURFACE 3) HALL WATER CLOSET REQUIRES 15" TO TUB 4) DUCT Y'S REQUIRE R-6 INSULATION 5) ALL REPEAT ITEMS, STOPPED INSPECTION 6) SUPERINTENDENT TO INSURE ALL TRADES 7) MEET PLAN AND CODE PRIOR TO NEXT INSPECTION OR REINSPECTION FEE WILL APPLY |
| 10/08/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0925*/ 1) WATER HEATER " B" VENT BROKEN 2) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE 3) NO DWV WATER TEST ON PLUMBING 4) HALL WATER CLOSET REQUIRES 15" CENTER LINE TO EDGE/WALL 5) LEAK UNDER HALL TUB/WET 6) DUCT Y'S REQUIRE R6 INSULATION 7) NO ELECTRIC TO ISLAND 8) ANCHOR BOLTS REQUIRE 12" OF SPLICES 9) NO CITY APPROVED PLAN ON SITE 10) STOPPED INSPECTION |