Permit: T03CM02630

Parcel: 116034980

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/23/2003 FRAMING Approved IVRS - Inspection 0000*
07/22/2003 FRAMING Denied IVRS - Inspection 0160*/ 1) INSTALL STRAPS AT GARAGE HEADER PER DETAIL 2) INSTALL SHEAR 5 NEAR WALK-THROUGH IN GARAGE PER DETAIL 3) SECURE HOLDOWNS AT SHEAR IN GARAGE 4) INSTALL A3.5'S AT 24" ON CENTER AT GARAGE GABLE 5) NAIL PLATE ELECTRICAL IN KITCHEN, MASTER BEDROOM, DINING AND LAUNDRY 6) REPLACE CONDUCTOR IN WALK IN CLOSET WALLS 7) WIRING IN HALL BATH ? 8) REMOVE DUCT FROM ATTIC ACCESS 9) A34 HEADER AT GARAGE WALK-THROUGH ALL HEADERS 10) ANCHOR SHEAR 5 AT 24" ON CENTER 11) INSTALL TRIPLE STUD IN GARAGE 12) INSTALL 2 X 8 RIDGE AND 2 X 6 HANGERS AT OVERFRAME 12) REPAIR PAPER AND BACKING AT ENTRY 13) AB'S AT 48" ON CENTER BAY 14) INSTALL A35'S AT GARAGE 15) SHIM HEADERS 16) CONNECT BOTH TOP PLATES AT LAUNDRY WALL
07/21/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*