Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/29/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
07/25/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) STUBBED TRUSS NOT CLIPPED OR BLOCKED 2) STRAIGHTEN RACKED TRUSSES 3) FHA STRAPS REQUIRE 6-16D NAILS EACH END 4) STRAIGHTEN WARPED TRUSSES 5) ROOF SHEATHING DOES NOT CONTACT TRUSSES AT RIDGE |