Permit: T03CM02594

Parcel: 116272140

Inspection Status: Approved

Inspection History: STEM WALL/RETAINING WALL

Permit Number - T03CM02594

Inspection Description - STEM WALL/RETAINING WALL

Inspection Status - Approved

Date Description Inspector Results Comments
10/01/2004 STEM WALL/RETAINING WALL Approved IVRS - Inspection :*
09/29/2004 STEM WALL/RETAINING WALL Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/20/2004 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) GARAGE, LOWER HALF
02/06/2004 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) PENDING APPROVAL OF CITY OF TUCSON PLAN REVIEW 2) INSTALL 4" CO PER PLAN OR REVISE
02/02/2004 STEM WALL/RETAINING WALL Denied IVRS - Inspection 0999* SEE PREVIOUS INSP
01/29/2004 STEM WALL/RETAINING WALL Denied IVRS - Inspection 0999*/ 1) BOND BEAM TO CLOSE TO TOP IN SEVERAL AREAS 2) 3/4" MAXIMUM BED JOINT THROUGHOUT 3) PART OF BOND BEAM MISSING AT REAR 4) SET BOND BEAM TO ALLOW GROUT IN CELLS
01/21/2004 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) PARTIAL FOR HIGHLIGHTED AREA ONLY IN YELLOW
11/06/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) WEST, SOUTH AND EAST EXTERIOR WALL