Permit: T03CM02577

Parcel: 121040020


Addresses:

5849 E NORTH ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
12/17/2003 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*/CORRECTIONS COMPLETED.
12/08/2003 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*/ WEST: 1) LIVING ROOM PLANS SHOWS A 5 DETECTOR 2) SM DETECTOR MIDDLE BEDROOM HAS TO BE 3' FROM MECH GRILL 3) MASTER BATH NAIL ROMEX WITHIN 12" OF EXHAUST FAN 4) MECH ROM LOW VOLTAGE WIRING IN LIGHT J-BOX TO BE SEPERATE 5) LIGHTING IN GARAGE MISSING-OR CHANGED, PLANS SHOWS INSIDE EAST: 1) LIVING ROOM PLANS CALLS FOR 5 DETECTOR 2) MECH ROOM LOW VOLTAGE IN BOX WITH 120V CONDUCTORS 3) VERIFY MID BEDROOM 5 DETECTOR 3' FROM REGISTER 4) MASTER BEDROOM BATH-EXHAUST FAN NAIL ROMEX WITHIN 12" OF FAN BOX 5) WATER HOSE BIB CANNOT BE UNDER ELECTRIC SUB PANEL 110.26