Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 01/12/2005 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
IVRS - Inspection :* |
| 09/10/2004 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 02/06/2004 |
PLUMBING - SEWER HCS CONNECT |
|
Denied |
IVRS - Inspection 0999*/ 1) CORRECTIONS MAKE OK 2) OK TO COVER |
| 02/03/2004 |
PLUMBING - SEWER HCS CONNECT |
|
Denied |
1) SDR 35 FITTING BACKPITCHED. INSPECTOR WILL REQUIRE FLOW TEST FROM UPSTREAM NOT WYE. PLUMBER TO BE ON SITE AT TIME OF NEXT INSP. 2) CONTRACTOR TO PAY RE-INSPECTION FEE. |
| 01/29/2004 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) 3042 HAS THE SAME ACTIVITY NO. 2) REVIEWED JOINT SEWER AGREEMENT ON FILE WITH COUNTY RECORDER. PLEASE RED LINE 'AS BUILT' ON SITE PLAN. 3) SDR 35 INSTALLED OK. OK TO COVER. 4) SDR CONNECTION AT CLAY BACKPITCHED. EXPOSE CLAY FITTING AND INSPECTOR WANTS TO WITNESS A FLOW TEST THROUGH THAT CONNECTION. |
| 01/15/2004 |
PLUMBING - SEWER HCS CONNECT |
|
Denied |
IVRS - Inspection 0999*/ 1) REQUIRE ΒΌ" PER FOOT FALL. 2) NOT INSTALLED PER PLAN. 3) wHICH IS 3042 AND WHICH IS 3046? NOT POSTED CLEARLY. / INSTALL PER PLAN OR REVISE PLAN AND PROVIDE JOINT SEWER AGREEMENT. |