Permit: T03CM02564

Parcel: 136327980

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/07/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
08/05/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) OK TO LATH
07/28/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) NEED TRUSS SHOP DRAWINGS, ON SITE, PLAN CALLS FOR HANGER AT LEDGER TO BE SPECIFIED BY TRUSS MANUFACTURER, YOU INSTALLED LUS 28'S WITH #8 TECO NAIL, WRONG NAIL, HANGER NOT SPECD 2) PLAN CALLS FOR 5 20 D NAILS LEDGER TO EXISTING STUD CAN'T FIND STUDS AT EXISTING PARAPET 3) NEED POSITIVE CONNECTION NEW ROOF TO OLD NORTH ADDITION 4) NEED VERTICAL LEG INSTALLED BY A TRUSS CO. WITH REPAIR, DETAIL STAMP BY ENG. 2) THEN TIE NEW ROOF TO EXISTING TRUSSES WITH STRAPS, OR H2.5
07/25/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*