Inspection History: SHEET ROCK NAILING

Permit Number - T03CM02550

Inspection Description - SHEET ROCK NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
11/13/2003 SHEET ROCK NAILING Approved IVRS - Inspection 0000*
11/10/2003 SHEET ROCK NAILING Denied IVRS - Inspection 0999*/ 1) SAG RESISTANT DRYWLL REQUIRED AT ALL CEILINGS. 2) DRYWALL 3/4" MAX. ON SOLE PLATES. 3) 8" NAIL SPACING MAX. ON WALLS - 12" WITH SCREWS. 4) NAIL CORNER AT KITCHEN LID, WALL EDGES. 5) NAIL EDGES THROUGHOUT. 6) INSTALL SOFFIT BOARD AT FRONT EXTERIOR.