Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/31/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 10/27/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*PLACE ADDRESS #S ON HOUSE. MOVE ELECTRIC OUTLET FROM BEHIND RANGE TO BE ACCESSIBLE 6" CLEARANCE IN FRONT OF FURNACE TO DOOR. REPAIR BROKEN H2O HEATER FLUE PIPE. HAVE GAS FURNACE ACCESSIBLE. MOVE H20 HEATER WATER LINE AWAY FROM P.T.R. VALVE. HAE H2O HEATER PTR VALVE OPERATE. INSTALL ELECTRIC FLEX INTO H20 HEATER PROPERLY. ALL ELECTRIC WIRES BELOW 8' TO BE PROTECTED( CONDUIT OR OTHERWISE) 100 AMP MAIN ELECTRIC SERVICE APPEARS UNDERSIZED FOR LOAD ( UPGRADE TO 200AMP) |