Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM02535
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/03/2003 | FRAMING | Approved | ||
11/25/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) TWO 3" ABS STACKS ONE GRAY WATER, ONE SEWER. FRONT BATH DON'T WET VENT 2ND FLOOR TO FIRST FLOOR EACH FIXTURE ON FIRST FLOOR TO HAVE IT'S OWN VTR ADD VENT STACK FOR 2ND FLOOR 2) CHECK ALL PEX WATER LINES AND STRAP PER CODE THEY ARE RATTLING 3) BANG PLATE AT MASTER CLOSET 4) LEAK AT HOT WATER HEATER 5) ISOLATE CU. AT STAIR, TAPE | |
11/21/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) WALLS OK, NEED TO CHECK LPI SPECS, REF BIRD MOUTH, SEAT CUT T-J'S 2) ATTACH LATH BEFORE COVERING INTERIOR MAIN HOUSE WALL | |
11/19/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SECURE ALL WIRES HANGING OUT OF CEILING 2) PROTECT ALL PLUMBING WHERE NEEDED 3) SUBS STILL WORKING | |
11/14/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) OK AT GARAGE ROOF OK TO CONTINUE TO SHEAR |