Date Description Inspector Results Comments
08/22/2003 ROOF NAILING Approved IVRS - Inspection 0000*
08/19/2003 ROOF NAILING Partial Approval IVRS - Inspection 0000*/ 1) TWO SMALL TRIANGLE SHAPE SHEAR TRANSFER WALLS TO NAIL TO DECK 2ND FLOOR 2) SHIM UNDER (DBL GIRDER) 3 PT BEARING 3) FRONT GARAGE SHEAR MISSING NAILS 4) MARKED ON WEST SHED ROOF, NAIL PERIMETER OF SHEETS TURNED WITH TRUSSES 5) FRONT DOOR TRIMMER NOT PLUMB