Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/30/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/29/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR 2) WATER LINES NOT PRESSURIZED 3) FRAMING WILL BE APPROVED WHEN ALL TRADES ARE COMPLETE 4) TJI BLOCK AT GARAGE NEEDS REPLACING |
|
| 06/27/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BANG PLATE WIRE AT TOP PLATE IN POWDER ROOM & ABS AT BOTTOM PLATE 2) BLOCK ALL DUCT BOOTS ON 3 SIDES. 3) ADD RED HEAD AT N.E CORNER. NORTH PLATE. 4) MOVE PEX 12" FROM CAN LIGHT IN LIVING ROOM 5) A-35 OR BLOCK TOPS & BUTS OF STRINGERS. 6) SHIM TRIMER/HEADER CONNECTS WHERE NEEDED. 7) BANG PLATE ABS AT SINK ATTACHMENT 2X IN SOUTH BATH. 8) NEED OUTLET WITHIN 6' OF S.E BED ENTRY DOOR. 9) SEAL ALL HOLES IN SUB FLOOR. 10) FINISH WIRING AT FID IN S.W. BEDS' BATH. 11) FHA STRAP DRYER DUCT AT TOP PLATE FRONT & BACK |