Permit: T03CM02469

Parcel: 133382770

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
07/09/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
07/08/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999* 1) CK ALL DRAINS FOR POSITIVE FLOW, 1/4" PER FT MIN. 2) 3X2 Y AT WATER CLOSET VENT SHALL A + 45 DEGREE MIN. FROM HORIZONTAL. 3) LONG SWEEP FITTINGS REQ'D ON HORIZONTAL. 4) 10- MIN, HIGH WATER TEST REQ'D ON PLBG SOIL. 5) CK UPSTREAM MANHOLE ELEVATION BACKWATER VALVE REQ'D. 6) WATER CLOSET DRAIN SHALL BE 12" FROM FINISH WALL TO CONFORM WITH APPROVED DRAWINGS. 7) SUGGEST 2-45 DEGREE USED INSTEAD OF 2-90 DEGREE. 8) EXT SEWER LINES SHALL BE PROTECTED WHEN LESS THAN 12" BELOW GRADE.
07/07/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*
06/30/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) UNVENTED TUB 2) UNVENTED TOILET 3) YOU NEED TO RETHINK YOUR PIPING 4) VENT THE TRAP ARM NOT THE TRUNK LINE 5) FLAT VENTING ROLL THE 45 DEGREE WYE UP TO UPPER 3RD OF TRUNK LINE 6) WET VENTING WET BENTED SECTION TO BE ONE PIPE SIZE LARGER THAN THE UPPER TRAP ARM 7) GLU CAP OFF OLD LAUNDRY 8) YOU NEED TO BE LOWER AT WALL LINE