Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T03CM02453

Parcel: 11516027G

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
06/24/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
06/09/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) I AM UNABLE TO DETERMINE HOW THE WATER CLOSET AND THE LAVATORY WERE CAPPED OFF-COVERED BEFORE INSPECTION 2) NOT INSTALLED PER PLAN. WE NEED AN ACCURATE PLAN SO THAT THIS SITUATION DOES NOT RE-OCCUR 3) REVISE PLAN SO THAT IT MATCHES AS BUILT NOTE: THERE IS NO 3" EXISTING VENT AT THIS LOCATION 4) PLEASE REVIEW 801.1 & 807.2 94 UPC-CONDENSATE WASTE MAY NOT BE DIRECTLY CONNECTED TO VENT, ALSO CONDENSATE DRAIN IS NOT SUPPORTED PROPERLY EVERY 4' MAXIMUM 5) USE APPROVED HANGERS 6) MUST DRAIN TO APPROVED LOCATION
06/01/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*