Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/24/2003 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000* |
| 06/09/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) I AM UNABLE TO DETERMINE HOW THE WATER CLOSET AND THE LAVATORY WERE CAPPED OFF-COVERED BEFORE INSPECTION 2) NOT INSTALLED PER PLAN. WE NEED AN ACCURATE PLAN SO THAT THIS SITUATION DOES NOT RE-OCCUR 3) REVISE PLAN SO THAT IT MATCHES AS BUILT NOTE: THERE IS NO 3" EXISTING VENT AT THIS LOCATION 4) PLEASE REVIEW 801.1 & 807.2 94 UPC-CONDENSATE WASTE MAY NOT BE DIRECTLY CONNECTED TO VENT, ALSO CONDENSATE DRAIN IS NOT SUPPORTED PROPERLY EVERY 4' MAXIMUM 5) USE APPROVED HANGERS 6) MUST DRAIN TO APPROVED LOCATION |
| 06/01/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999* |