Inspection History: MECHANICAL - FINAL

Permit Number - T03CM02451

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/22/2004 MECHANICAL - FINAL Approved IVRS - Inspection :*/INSULATE SUPPLY DUCT IN ATTIC. OK FOR FINAL C/O
11/16/2004 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*/INSULATE REFER LINE ON CU-1. SECURE ALL REFER LINES SUCTION TO DISCHARGE. A/C 2 INSULATE SECTION OF SUPPLY DUCTS IN ATTIC. PROVIDE OVER FLOW SENSOR ON UNIT #8 DRYERS & WATER HEATERS OK. PROVIDE DISCONNECTS ON WALK IN COOLERS. NEED TO CHECK CIRCUIT BREAKERS. CU1-20/25 2-20/30 3, 25/35 4-20/30 5-20/25 6-20/25 7-20/35 8-15/20
10/26/2004 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*/OK FOR TEMP C/O
10/19/2004 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/CAP OFF VENT ON CONDENSATE DRAIN LINES UPSTREAM OF TRAP. LABEL FAN COILS. RELOCATE ELEC. CONDUIT. SECURE FURNACE VENT UNIT #2. INSULATE SUPPLY DUCT FROM UNIT #3. REPLACE DAMAGED DUCT. FINISH CONNECTING OVERFLOW SENSORS. PROVIDE MIN. 6" CLEARANCE FROM SINGLE WALL VENTS
10/14/2004 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/MAINTAIN MIN. 6" CLEARANCE TO COMBUSTIBLES ON SINGLE WALL VENT CONNECTORS. DO NOT ADAPT FROM DOUBLE WALL TO SINGLE WALL. INSULATE ALL SUPPLY & RETURN DUCTS. REMOVE FSK TAPE FROM VENT CONNECTORS. CAP OFF VENT UPSTREAM OF CONDENSATE TRAPS. REPAIR REFER LINE INSULATION. CONNECT OVERFLOW SENSOR WIRING. IDENTIFY FAN COILS. RELOCATE ELEC. CONDUIT FROM BLOCKING ACCESS TO FAN COILS ON EAST SIDE OF BLDG. DUCT IS BEING USED AS A STEPPING STOOL