Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T03CM02451
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/19/2004 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :*/REVISED PLAN ON SITE | |
09/13/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* NOT READY | |
09/08/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/2" DRAIN FOR EMERGENCY EYE WASH IN POOL EQUIP. ROOM WATER TEST . WASTE & VENT THRU ROOF OK PENDING REVISED CITY APP. PLAN WITH ADDITION OF THIS FIXTURE | |
07/13/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/ 1) WATER TEST ON 4" POOL EQUIPMENT FLOOR DRAIN OR SINK UNDERGROUND OK | |
05/10/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/ 4" BLD SEWER TIE TOGETHER ON WEST SIDE OF GATE HOUSE PER PLAN INITIALED ON 5/10/04 WTR TEST OK. | |
04/12/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*/ REVISED CITY APPROVED DRAWING ON SITE SHOWING RED LINE INSTALLATION. | |
04/08/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*/ | |
04/02/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*/ 6PSI AIR TEST ON WASTE AND VENT UNDERGROUND ONLY ROOMS 137-140, UP TO TEST WYE, JUST BEFORE ROOM 136. NEED TO TERMINATE END OF LINE 4" CLEAN OUTS VERTICAL AND ADD DRAIN FOR LAV IN ROOM 139. | |
03/16/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000* | |
03/10/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*/ WTR TEST ON 4" FLOOR DRAIN FOR WASHING MACHINE AREA WITH 2" VENT PARTIAL APPROVAL PENDING CITY APPROVED DRAWING SHOWING SIZE AND ACTUAL INSTALLATION. COVER AT YOUR OWN RISK. (GATE HOUSE) | |
03/09/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*/ 8" SITE SEWER WTR TEST FROM MANHOLE INSTALLED PER PLAN AS HIGHLIGHTED ON CV-1 OK. WILL NEED VERIFICATION OF GRADE. / 2" H2O STUBBED OUT OF UNDER BLD SLAB OUTSIDE 4' AT MECH ROOM #157. 100 PSI TEST PARTIAL APPROVEL PENDING CITY APPROVED DRAWING SHOWING CHANGE IN LOCATION. | |
03/05/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*/ GATE HOUSE EAST END UNDERGROUND FOR WASHING MACHINE ROOM, AND MECH. ROOM. | |
03/02/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*/ GREASE WASTE FOR KITCHEN AREA AIR TEST UNDERGROUND PARTIAL APPROVAL WILL REQUIRE CITY APPROVED DRAWING OF INSTALLATION AND GREASE TRAP ORIENTATION. 4" SANITARY SEWER IN GATE HOUSE PARTIAL APPROVAL AIR TEST WILL NEED TO SEE POOL EQUIPMENT AREA, WTR HTR ROOM AND MAIN LAUNDRY ROOM. | |
03/01/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) INSTALL PER PLAN OR HAVE CITY APPROVED PLAN SHOWING INSTALLATION 2) HUB DRAIN ARE NOT APPROVED SANITARY DRAIN RECEPTORS. PROVIDE APPROVED DRAIN RECEPTORS. 3) FULL SIZE CLEANOUTS WILL BE REQUIRED ON HORIZONTAL DRAINAGE 4) AIR TEST ON TRUNK SEWER PARTIAL APPROVAL FOR BACKFILL |