Permit: T03CM02424

Parcel: 128102930

Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Permit Number - T03CM02424

Inspection Description - SHEET ROCK NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
11/03/2004 SHEET ROCK NAILING Approved IVRS - Inspection :*/OK TO COMPLETE SMALL AREAS & TAPE
10/01/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*PARTIAL APPROVAL. OK TO TAPE COMMON AREAS & STAIRS LEAVE OPENINGS IN ROCK FOR PENETRATION INSPECTION.
09/24/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*/GUEST SUITES COMPLETE. MECH/ELEC ROOMS & STAIR WALK REMARK?
09/23/2004 SHEET ROCK NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/23/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*2) IMPROPER FIRE STOP AT CONDUIT E 419, 417, 416, 413 ETC...
09/20/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*/ 1) OK ROOMS AT 4TH FLOOR EAST OF COMMON AREA (FIRE WALLS)
09/17/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*/ 1) OK ROOMS AT 4TH FLOOR EAST COMMON AREA EXCEPT FIREWALLS
09/13/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
08/26/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
08/24/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*/PARTIAL- E 1/2 3RD FKIIR REPAIR AS NOTED
01030-1)PRONDE STAMPED RFI, CONCERNING SUPPORTS ON TRUSSLE 5" OFF CENTER OF BEARING
2)HIP & JACKS 43-46 DO NOT BEAR PER DESIGN
3) RFI FOR TRUSS #42 OF CENTER AT EXTERIOR BEARING BY 8"-10"
4) REPAIR FOR CEMT.? #42 TRUSSES USED WRONG HANGER-RFI FOR # OF NAILS
5)HANGERS NOT NAILED @ LVL
6) "X" BRACING ALONG NE RIDGE
08/23/2004 SHEET ROCK NAILING Not ready for Inspection IVRS - Inspection :*
08/16/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*/PARTIAL-WEST 1/2 2ND FLOOR
08/12/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*/ 1) E 1/2 2ND FLOOR OK
08/04/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*/ 1) W 1/2 1ST FLOOR
07/30/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*/ 1) OK TO ROCK 2ND FLOOR 2) E 1/2 1ST FLOOR
07/28/2004 SHEET ROCK NAILING Not ready for Inspection IVRS - Inspection :*
07/26/2004 SHEET ROCK NAILING Not ready for Inspection IVRS - Inspection :*
07/22/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :OK TO TAPE MODEL ROOMS EXCEPT @ PENETRATIONS WHERE FIRE STEP REQUIRED
05/18/2004 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*/ 1) PROVIDE LISTED SYSTEM FOR 1 HOUR FLOOR SEPERATIONS 2) PROVIDE LISTED FIRE STOP SYSTEM FOR PENETRATIONS 3) FIRE STOP REQUIRED AT ELECTRIC OUTLETS WHRE BACK TO BACK