Permit: T03CM02424

Parcel: 128102930

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/23/2004 FRAMING Approved IVRS - Inspection :*
09/09/2004 FRAMING Partial Approval IVRS - Inspection :*
09/08/2004 FRAMING Partial Approval IVRS - Inspection :*/CAT WALK FRAMING OK
1)PLASTIC REFRIDGERATOR WATER SUPPLY BOXES IN FIRE WALLS NEED TO BE SWITCHED OVER WITH METAL ONES
09/01/2004 FRAMING Partial Approval IVRS - Inspection :I AM REQUESTING THAT DESIGN ENGINEER OF RECORD INSPECT AND PROVIDE SEALED APPROVAL OF TRUSS SYSTEM AS INSTALLED AND REPAIRED
08/26/2004 FRAMING Partial Approval IVRS - Inspection :W 1/2 4TH FLOOR OK TO ROCK WALLS
W 1/2 3RD FLOOR OK
FINISH REPAIRS ON HOLES IN CORRIDOR
TRUSSES OFF BEARING BY 8"
MAKE REPAIRS @ SE CORNER AS NOTED
NAIL HANGERS @ LVL
ALL FOSSET REPAIRS TO BE NAILED @ 2" O.C.
#32 TRUSSES MISS BEARING POINTS @ EXTERIOR SOUTH WALL
08/25/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
08/24/2004 FRAMING Partial Approval IVRS - Inspection :*/PARTIAL 1) E 1/2 4TH FLOOR OK TO ROCK WALLS 2)CAP WITH ROCK OVER SHAFTS
08/23/2004 FRAMING Partial Approval IVRS - Inspection :*
08/20/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
08/19/2004 FRAMING Partial Approval IVRS - Inspection :3RD FLOOR READY TO INSULATE & ROCK CEILINGS
FOOTING FOR 6' SCREEN WALL AROUND POOL OK PER PAG SPECS
08/13/2004 FRAMING Partial Approval IVRS - Inspection :3RD FLOOR - OK TO ROCK WALLS ONLY
I NEED TO SEE ABOVE CEILING
08/09/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
08/05/2004 FRAMING Cancelled IVRS - AP canceled
08/05/2004 FRAMING Cancelled IVRS - AP canceled
07/29/2004 FRAMING Cancelled IVRS - AP canceled
07/28/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) YOU NEED TO COMPLETE AT LEAST 1/2 OF EACH FLOOR BEFORE CALLING INSPECTION-INCLUDING CORRIDOR
07/20/2004 FRAMING Partial Approval IVRS - Inspection :1ST FLOOR OK ELEVATOR SHAFT OK
OK TO ROCK ENTIRE 1ST FLOOR
I WOULD LIKE TO SEE INSULATION WHEN BLOWN IN
07/19/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
07/16/2004 FRAMING Cancelled IVRS - AP canceled
07/09/2004 FRAMING Partial Approval IVRS - Inspection :*OK TO ROCK EAST 1SR FLOOR WALL ONLY.
07/07/2004 FRAMING Partial Approval IVRS - Inspection :* MAKE REPAIR @ #216 WHERE LIFT DAMAGE
07/06/2004 FRAMING Cancelled IVRS - AP canceled
06/29/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) 3RD FLOOR OK FOR ABOVE CEILING ROCK AND FOR CORRIDOR ROCK
06/28/2004 FRAMING Cancelled IVRS - AP canceled
06/23/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) CORRIDOR CEILING WEST UP TO ELEVATOR 2) ELECTRIC ROOM CEILING JOIST CHANGE
06/22/2004 FRAMING Cancelled IVRS - AP canceled
06/16/2004 FRAMING Partial Approval 1) 1ST FLOOR PROGRESS OK 2) PROVIDE FIRE BLOCKS 10' ON CENTER HORIZONTAL WHERE NOT CHANNEL OR 'Z' CHANNEL USED ON FRAMING
06/15/2004 FRAMING Cancelled IVRS - AP canceled
06/09/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) OK TO ROCK 2ND FLOOR CORRIDOR LIDS
06/08/2004 FRAMING Cancelled IVRS - AP canceled
06/03/2004 FRAMING Partial Approval IVRS - Inspection :* OK TO ROCK CORRIDORS LIDS & SIDES
05/25/2004 FRAMING Partial Approval IVRS - Inspection :*/1) INTERIOR SW NOT FULLY BLOCKED-GET RFI
05/18/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) SHEAR NAILING REQUIRED ALL EDGES. REPAIR BLOCKING AS NEEDED 2) USE METAL SHIMS WHERE HEADERS NOT CONTACTING TRIMMERS 3) SHEAR WALLS MORE THAN 1 UNIT PANEL IN HEIGHT REQUIRE STAGGERED JOINTS (S3.3) 4) HOW DOES ENGINEER WANT 2 X 10 LEDGERS FASTENED TO HALL WALLS ? (6/S3.2)
04/15/2004 FRAMING Not ready for Inspection IVRS - Inspection :*